Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | On-line |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical Specification | ||||||
Model | INTT10K | INTT15K | INTT20K | INTT30K | INTT40K | |
Capacity(VA/W) | 10K/8K | 15K/12K | 20K/16K | 30K/24K | 40K/32K | |
Battery Voltage | 384V | |||||
UPS Efficiency | ≥90% | |||||
Noise | 48-54dB(1) 48-54dB(Distance 1m) |
53-60dB(1) 53-60dB(Distance 1m) |
||||
Size(W × D × H mm) | 555 × 725 × 1220 | |||||
Weight(kg) | 200 | 235 | 260 | 315 | 335 | |
Input |
Voltage | + 3 phases 4 wires and ground, 380V ± 25% | ||||
Frequency | 50Hz/60Hz ± 5% | |||||
Soft-starting | 0-100% 10 seconds | |||||
Power Factor | ≥0.95 | |||||
Inverter Output |
Voltage | 3 phases 4 wires, 380V ± 1% | ||||
Frequency | 50Hz/60Hz ± 0.05% | |||||
Harmonic Distortion |
3%, 5% Linear load 3%, Non-linear load 5% |
|||||
Imbalance Voltage |
≤ 1%,100% ≤ 3% Balance Load ≤ 1%, 100% unbalance load ≤ 3% |
|||||
Dynamical Response |
0% - 50% - 100%, ≤ 10ms Output dynamical 0% - 50% - 100%, Response time ≤ 10ms |
|||||
Overload Capacity |
110% ≥ 300Min, 125% ≥ 10Min, 150% ≥ 1Min | |||||
Crest Factor | 3:1 | |||||
Waveform | Sine Wave | |||||
Transfer Time | 0ms | |||||
Battery |
Max. Charging Current |
0.2A × C10 | ||||
() Charging Time(Standard) |
12 12Hours | |||||
Control System |
Protection Function |
,,, Input over-voltage & under-voltage, Output overload & short circuit, Rectifier & Inverter over-temperature, Battery low-voltage & over-charging |
||||
Running Temperature & Humidity |
0-40ºC, 0-95% Temperature 0-40ºC, Humidity 0-95% |
|||||
Altitude | 1000(10001001%),4000 1000m (Above 1000m, output will reduce 1% every increasing 100m),Max 4000m |
|||||
IP Degree | IP20 | |||||
Communication Interface | RS232 | |||||
Remote | (,,/) DRY-Contact(Battery low, Battery discharging, Bypass/Fault) |
|||||
EPO | Standard equipped EPO | |||||
Parallel Mode | 8 Max 8 units in parallel mode | |||||
OS | Window 9X/2000/XP, Linux, Novell, Mac OS, NT4.0 | |||||
Optional | ,,,ECO mode(Below 100K) Dust proof net, Conformal coating, Input isolation transformer, ECO mode(Below 100K) |
Technical Specification | ||||||
Model | INTT10K | INTT15K | INTT20K | INTT30K | INTT40K | |
Capacity(VA/W) | 10K/8K | 15K/12K | 20K/16K | 30K/24K | 40K/32K | |
Battery Voltage | 384V | |||||
UPS Efficiency | ≥90% | |||||
Noise | 48-54dB(1) 48-54dB(Distance 1m) |
53-60dB(1) 53-60dB(Distance 1m) |
||||
Size(W × D × H mm) | 555 × 725 × 1220 | |||||
Weight(kg) | 200 | 235 | 260 | 315 | 335 | |
Input |
Voltage | + 3 phases 4 wires and ground, 380V ± 25% | ||||
Frequency | 50Hz/60Hz ± 5% | |||||
Soft-starting | 0-100% 10 seconds | |||||
Power Factor | ≥0.95() | |||||
Inverter Output |
Voltage | 3 phases 4 wires, 380V ± 1% | ||||
Frequency | 50Hz/60Hz ± 0.05% | |||||
Harmonic Distortion |
3%, 5% Linear load 3%, Non-linear load 5% |
|||||
Imbalance Voltage |
≤ 1%,100% ≤ 3% Balance Load ≤ 1%, 100% unbalance load ≤ 3% |
|||||
Dynamical Response |
0% - 50% - 100%, ≤ 10ms Output dynamical 0% - 50% - 100%, Response time ≤ 10ms |
|||||
Overload Capacity |
110% ≥ 300Min, 125% ≥ 10Min, 150% ≥ 1Min | |||||
Crest Factor | 3:1 | |||||
Waveform | Sine Wave | |||||
Transfer Time | 0ms | |||||
Battery |
Max. Charging Current |
0.2A × C10 | ||||
() Charging Time(Standard) |
12 12Hours | |||||
Control System |
Protection Function |
,,, Input over-voltage & under-voltage, Output overload & short circuit, Rectifier & Inverter over-temperature, Battery low-voltage & over-charging |
||||
Running Temperature & Humidity |
0-40ºC, 0-95% Temperature 0-40ºC, Humidity 0-95% |
|||||
Altitude | 1000(10001001%),4000 1000m (Above 1000m, output will reduce 1% every increasing 100m),Max 4000m |
|||||
IP Degree | IP20 | |||||
Communication Interface | RS232 | |||||
Remote | (,,/) DRY-Contact(Battery low, Battery discharging, Bypass/Fault) |
|||||
EPO | Standard equipped EPO | |||||
Parallel Mode | 8 Max 8 units in parallel mode | |||||
OS | Window 9X/2000/XP, Linux, Novell, Mac OS, NT4.0 | |||||
Optional | ,,,ECO mode(Below 100K) Dust proof net, Conformal coating, Input isolation transformer, ECO mode(Below 100K) |